When choosing a roof gutter system, we should make sure whether troughs and downspouts will be able to collect water from the roof area of our building. For this, calculate the so-called effective roof area, which is to be drained by the system.
Maximum surfaces drained by GAMRAT roof gutter systems in sq. m. of effective roof area (per downspout).
|
Roof gutter
system
|
75-mm System
|
100-mm System
|
125-mm System
|
|
Positioning of
down-
spout pipe
|
75-mm trough Down-
spout of 63 mm
|
100-mm trough Down-
spout of 90 mm
|
125-mm trough Down-
spout of 110 mm
|
125-mm trough Down-
spout of 63 mm
|
|

|
95
|
148
|
240
|
165
|
|

|
48
|
74
|
120
|
82
|
|

|
42
|
50
|
95
|
65
|
|
The following formula may be used for calculation of the effective roof area:
S = (B + 0,5 C) x L

|
|